System Diagnostics
Alarm Diagnostics
When arming or disarming the alarm, this system will alert you of
alarm triggers or active inputs.
Arming Diagnostics:
When arming, if the door or hood is open the Horn/Siren output
and Parking Lights will pulse three times instead of once.
The LED will flash pause, and then repeat 5 times to indicate the
active input. (See alarm input chart.)
The active input will be bypassed. When it has been active for
more than 5 seconds it will be monitored by the system again. All
other alarm inputs will be monitored normally to assure the secu-
rity of the vehicle
Disarming Diagnostics:
When disarming, if the alarm was fully triggered in your absence,
the Horn/Siren output and Parking Lights will pulse four times
instead of twice.
The LED will flash pause, and then repeat 5 times to indicate the
input that caused the trigger (See alarm input chart).
Note! If the alarm was triggered more than once, the
diagnostics will only report the last input that fully
triggered the alarm.